Sort:
Search:



INTRODUCTORY NOTES
Before assembling, connecting and using the device, please read this manual carefully. In case of any problems with understanding its content, please contact the seller of the device. Self-assembly and commissioning of the device is possible provided that the appropriate tools are used. Nevertheless, it is recommended that the device be installed by qualified personnel.
The manufacturer is not responsible for any damage that may result from improper installation or operation of the device, as well as from performing independent repairs and modifications.

1. CHARACTERISTICS OF THE EXTERNAL CASSETTE
Equipped with a protective roof, the external cassette, designed for surface mounting, with a protection factor of IP65, enables the correct operation of the video intercom even in difficult weather conditions. The high-quality camera provides excellent image
parameters, also at night - thanks to 6 IR LEDs and a twilight sensor that allows you to view the surroundings of the external cassette with insufficient light intensity. In addition, the device allows you to enter using a code - the encrypted backlight makes it
easier to operate the device at night.

2. CONSTRUCTION OF THE EXTERNAL CASSETTE
The structure of the VDA-50C5 external cassette is shown in fig. 1.

Fig. 1 Construction of the external cassette

3. INSTALLING THE EXTERNAL CASSETTE
The external cassette is factory-adapted for surface mounting

(!) Attention!
The correct location of the external cassette determines the comfort of working with the device. Hence, it is recommended to experimentally select the place of installation of the external cassette before drilling the assembly hole. To do this, first install the monitor by connecting it (according to the recommendations in "Monitor Installation") with the external cassette, which should be held by another person during the test. Next, connect the mains power and start choosing the right place for the installation of the external cassette. The person holding the external cassette should simulate normal operation of the device and call the second person at the monitor by pressing the call button. During this time, the person at the monitor should observe the camera's field of view. The person holding the external cassette, based on the suggestion of his interlocutor, has to set it in the optimal position.

(!) Attention!
If the cassette is installed in a place not protected against rainfall, it is necessary to install a cover above the cassette to prevent water from getting inside.
DAMAGE CAUSED BY FLOODING CASSETTE IS NOT COVERED BY THE WARRANTY!
Fig. 2

Fig. 3

(!)
Attention!
Do not make any connections or changeover of cables while the device is connected to the power supply. Failure to do so may damage the device! Disconnect the power supply before assembling or disassembling the device!

Practical considerations regarding the installation of the external cassette
Avoid places where the camera lens is exposed to direct, perpendicular exposure to light rays (sun, headlights, street lighting), as this may cause its incorrect operation and asignificant reduction in visibility.

4. DIAGRAM OF WIRING CONNECTION
The system connection diagram, which includes: external cassette, monitor, electromagnetic bolt, entrance gate or garage door automation and power supplies is shown in Fig. 4.

* An element of additional equipment, not included in the set.
Fig. 4. Diagram of connections for a standard electric strike

5. DESCRIPTION OF THE DEVICE OPERATION
1. Action
The device supports up to 200 cards / tags and 200 different PIN codes. Access can beobtained in 3 ways: by card, card or PIN code, card + PIN code.

2. Capacity
200 cards / fobs, 200 PIN codes (assigned to fob cards) and 1 access password (6-digit).

3. Restore factory settings
Remove the 12VDC power from the external rack, then press and hold the input buttonwhile restoring power. After you hear three "bi" signals, release the input button (see connection diagram - blue and gray wires). The factory settings have been restored.

Factory master code: 999999, general access password: 123456.
Factory access method: card or PIN code.
The factory release time of the electric strike: 3s.
Emergency mode is turned off at the factory.

In standby mode, the keyboard buttons are slightly illuminated, while when the keyboard is awakened, it becomes more illuminated. The doorbell button has a permanent bright backlight.
When the device is on a call, monitoring or motion detection, the doorbell button lights up in red. When the electric strike is released, the color of the bell button illumination changes to green.

(!)  ATTENTION!
Restoring factory settings does not erase all saved data.

(!) ATTENTION!
All operations must be performed in the programming mode*kodmaster #.

4. Programming mode
To enter the programming mode: press * + (default: 999999) + #, you will hear a double “bi” sound and the button illumination will start flashing slowly. And then you will hear a triple bi-sound. The device will automatically exit the programming mode after 30 seconds and will be confirmed with a triple “bi” sound. When entering new settings, a double “bi” sound indicates the correct completion of the process. If the entered data is incorrect or new settings have not been entered successfully, you will hear a "bi" beep 4 times.

1. Changing the master code, general password and restoring factory settings.
1.1 Changing the master code Master code:
Press 0 (button light flashes quickly) + 77 + # NNNNNN (6 digit password) + # + NNNNNN (re-enter password) + #.

1.2. Change of the general password General access password:
Press 0 (button light flashes quickly) + 11+ # NNNNNN (6-digit password) + # + NNNNNN (re-enter password) + #.

1.3 Factory Reset Factory Reset:
Press O (button light flashes quickly) + 99 + # (you will hear a "bi" sound. The button illumination is flashing slowly), the device has returned to its factory settings.

2. Programming the card / tag
Press 1 (the button backlight is flashing quickly) + 000 ~ 999 (select from the range e.g.001) + # + present card / tag. you will hear a double "bi" sound, which means the card / tag has been added successfully. 4 beep. "Bi" means adding card failed. After adding a
new card / tag, the factory default password is 0000.

This password is not used to control access, but to enter a new password.

3. Deleting a card and tag
To change the standard password, press *, hold the card / tag close to the reader and enter 0000 # (two "bi" signals), then enter a new 4-digit PIN code, confirming # and repeat the PIN code, confirming #.

Example for code 8888: * keychain / card 0000 # 8888 # 8888 #

Press 2 (the button backlight is flashing quickly) + NNN + # (NNN stands for the number of any card / tag from 000 to 199 that you want to delete). A triple beep "bi" means that the deletion of the card / tag and the assigned PIN code was successful. Deleting uploaded cards / tags

Press 2 (button backlight flashes quickly) + read card / tag. you will hear a double beep .bi”, which means that the card / tag and the assigned PIN code have been success fully deleted. Delete all cards Press 2 (button light flashes quickly) +88 + # (you will hear seven times "bi", button light slowly flashes), it means all information has been deleted.

4. Regulation of the release time of the electric strike
Press 4 (button light flashes quickly) + 00 ~ 99 (select from range) + # (you will hear a double “bi” sound, the button light is flashing slowly). Adjustment of the release time of the electric strike has been successful. If we enter the value 02, it means that the electric strike will be released for 2 seconds. If we enter the value 00 it means that we have to
bring the card closer to open it and then bring it back to close it.

5. Security mode settings
Press 5 (button light flashes quickly) + 00 + # (you will hear a double bi-sound, button light flashes slowly) - the security mode is disabled.

Press 5 (button light flashes) +01 + # (you will hear a double “bi” beep, button light is flashing slowly) ----

Lock Mode: means: if an invalid card is repeatedly presented within 5 minutes or 10 wrong passwords have been entered, the device will lock for 2 minutes, the button illumination will flash quickly and the connection to the indoor panel will be established automatically. During the blockade, the device does not read cards and does not respond to pressing the buttons on the keyboard, with the exception of the bell button.

Press 5 (button light flashes) + 02 + # (you will hear a double “bi” sound. Button light flashes slowly) ----

Alarm mode: means that if within 5 minutes an invalid card is repeatedly presented or 10 wrong passwords are entered, the device will lock and alarm for 1 minute, the button illumination will flash quickly and the connection to the indoor panel will be established
automatically. During the blockade, the device does not read cards and does not respond to pressing the buttons on the keyboard, except for the bell button.

(!) Attention!
While following the steps above, press "*" to exit or return to the previous step.

6. Operation of the device by the user

(!) Attention!
The following operations must be performed outside of programming mode.

Password change
Press *, present the card + enter the old PIN code + # (by default 0000, you will hear a double "bi" signal, the button backlight is slowly blinking). NNNN (4-digit code for new password).

Opening the door with a card / tag
Place a valid card / tag close to the reader on the cassette. The electric strike will be released.

Opening the door with a card / key ring or PIN code
Place a valid card / tag near the reader on the cassette or enter a 4-digit password on its
keyboard.
Accept by pressing #. If the card / tag or PIN code is correct, the electric strike will be
released.

Opening the door with a card / tag and password
Present a valid card / tag to the reader on the cassette and enter a 4-digit password and accept
by pressing #.
If the card / tag and PIN code are correct, the electric strike will be released.

6. PROGRAMMING SETTINGS - SHORT MANUAL



Eura-Tech Sp. z o. o. hereby declares that the type of the radio device - external video intercom cassette
VDA-50C5 - complies with directive 2014/53 / EU.
Full text of the EU declaration of conformity is available under the following web address:
www.eura-tech.eu

EURA-TECH Sp. z o.o.
ul. Przemysłowa 35A, 84-200 Wejherowo, Poland
www.eura-tech.eu
All rights reserved.
The pictures, drawings and texts used in this manual are the property of ‘EURA-TECH’ Sp. z o.o.
Reproduction, distribution and publication

of the whole or parts of the manual without the author's consent are prohibited!
The Eura-Tech Sp. z o.o. company reserves the right to change technical parameters and modify the operating instructions without notification.
At the same time, we would like to inform that the most up-to-date version of the manual can be found on the website www.eura-tech.eu
on the subpage of the given product.
The EU declaration of conformity of the given device is provided on the http://www.eura-tech.eu website