PRELIMINARY NOTES
Before assembling, connecting and using the device, please read this manual carefully. In case of any problems with understanding its content, please contact the seller of the device. Self-assembly and commissioning of the device is possible provided that the appropriate tools are used. Nevertheless, it is recommended that the device be installed by qualified personnel.
The manufacturer is not responsible for any damage that may result from improper installation or operation of the device, as well as from performing independent repairs and modifications.
1. Characteristics of the outer case
Equipped with a protective canopy, the external cassette is designed for surface mounting, with a protection factor of IP65, which enables the correct operation of the video intercom even in difficult weather conditions. The high-quality camera ensures excellent image parameters, also at night - thanks to the IR LEDs and the twilight sensor, which enables the viewing of the surroundings of the external cassette with insufficient light intensity. In addition, the device allows you to enter using a code - the encrypted backlight makes it easier to operate the device at night.
2. Construction of the external cassette
The structure of the VDA-51C5 external cassette is shown in Fig. 1.
Fig. 1 Construction of the external cassette
3. installation of the external cassette
The external cassette is factory-adapted for surface mounting.
practical notes on the assembly of the external cassette
Avoid places where the camera lens is exposed to direct, perpendicular exposure to light rays (sun, headlights, street lighting), as this may cause its incorrect operation and significantly reduce visibility.
(!) ATTENTION!
The correct location of the external cassette determines the comfort of working with the device. Hence, it is recommended to experimentally select the place of installation of the external cassette before drilling the assembly hole. To do this, first install the
monitor by connecting it (according to the recommendations in "Monitor Installation") with the external cassette, which should be held by another person during the test. Next, connect the mains power and start choosing the right place for the installation of
the external cassette. The person holding the external cassette should simulate normal operation of the device and call the second person at the monitor by pressing the call button. During this time, the person at the monitor should observe the camera's field
of view. The person holding the external cassette, based on the suggestion of his interlocutor, has to set it in the optimal position.
(!) ATTENTION!
If the cassette is installed in a place not protected against rainfall, it is necessary to install a cover above the cassette to prevent water from getting inside.
DAMAGE CAUSED BY FLOODING CASSETTE IS NOT COVERED BY THE WARRANTY!
Fig. 2
Method of mounting a surface-mounted cassette:
- Unscrew the 2 bottom fixing screws and separate the cassette from the protective canopy.
- Mark the places for the mounting pins on the wall through 4 holes in the protective roof.
- Drill 4 Ø5mm mounting holes in the marked places and then place 4 mounting pins in them.
- Use 4 mounting screws to fix the protective canopy to the wall.
- Connect all necessary cables to the external cassette.
- Place the outer cassette in a protective canopy attached to the wall using the hole for attaching the canopy and screw in the 2 bottom fixing screws.
(!) ATTENTION!
Do not make any connections or changeover of cables while the device is connected to the power supply.
Failure to do so may damage the device! Disconnect the power supply before assembling or disassembling the device!
4. Wiring diagram
The system connection diagram, which includes: external cassette, monitor, electromagnetic bolt, entrance gate or garage door operator and power supplies is shown in Fig. 5.
* An element of additional equipment, not included in the set.
Fig. 4. Connection diagram
* An element of additional equipment, not included in the set.
Fig. 5. Connection diagram with the use of one common 12V DC power supply min. 4A.
5. description of the device operation
1st action
The external cassette is equipped with 2 independent outputs that can be controlled with
separate codes or cards / fobs.
2nd capacity
Input 1: 200 cards / key fobs, 200 PIN codes (assigned to key fobs) and 1 access password (6-digit).
Entrance 2: 100 cards / key fobs, 100 PIN codes (assigned to key fobs) and 1 access password (6-digit).
3. Factory reset
Disconnect power to the external cartridge, then press and hold the call button while restoring power. After you hear three "bi" beeps, release the call button. The factory settings have been restored.
Factory default general password forinputs 1:123456
Factory default general password forinputs 2:456789
Factory access method: card or PIN code. The factory
release time of the electric strike: 2s.
Emergency mode is turned off at the factory.
In standby mode, the keyboard buttons are slightly illuminated, while when the keyboard is awakened, it becomes more illuminated. The doorbell button has a permanent bright backlight.
When the device is on a call, monitoring or motion detection, the doorbell button lights up in red. When the electric strike is released, the color of the bell button illumination changes to green.
(!) ATTENTION!
Restoring factory settings does not erase all saved data.
(!) ATTENTION!
All operations must be performed in the programming mode*kodmaster #
4th programming mode
To enter the programming mode: press*+ (default:999999) +#, you will hear a double “bi” sound and the button illumination will flash slowly. And then you will hear a triple bi- sound. The device will automatically exit the programming mode after 30 seconds and
will be confirmed after a triple beep "bi". When entering new settings, a double “bi” sound indicates the correct completion of the process. If the entered data is incorrect or new settings have not been entered successfully, you will hear a "bi" beep 4 times.
Entering the programming mode:*999999 #
1. Changing the master code, general password and restoring factory settings.
1.1 Changing the master code
Enter the programming mode then press0(the button illumination flashes rapidly) +77+#+NNNNNN(6-digit password) +#+NNNNNN(re-enter password) +#.
Example: * 999999 # 077 # 222222 # 222222 #
1.2. Changing the general password for Input 1.
Enter the programming mode then press0(the button illumination flashes rapidly) +11+#+NNNNNN(6-digit password) +#+NNNNNN(re-enter password) +#.
Code example444444: * 999999 # 011 # 444444 # 444444 #
1.3 Factory Reset
Factory reset: pressABOUT(the button illumination flashes rapidly) +99+#(you will hear a "bi" sound. button illumination flashes slowly), the device is reset to factory settings.
2. Programming card / tag for Zone 1.
Enter the programming mode then press1(the button illumination flashes rapidly) +000~999(choose from the range e.g. 001) +#+present the card / tag. you will hear a double "bi" sound, which means the card / tag has been added successfully. 4 beep. "Bi" means adding card failed. After adding a new card / tag, the factory default password is 0000.
This password is not used to control access, but to enter a new password.
In order to change the standard code, press *, hold the card / tag close to the reader and enter it0000+#(two "bi" beeps), then enter a new 4-digit PIN code to confirm#and repeat the PIN code, confirming#. Example for code 8888:
* keychain / card 0000 # 8888 # 8888 #
3. Deleting card and tag for Zone 1.
3.1. Deleting a lost card / tag.
Enter the programming mode then press2(the button illumination flashes rapidly) +NNN+#(NNN means the number of any card / tag from 000 to 199 that you want to delete).
Triple "bi" sound means that the card / tag and the assigned PIN code have been deleted.
3.2. Deleting uploaded cards / tags.
Enter the programming mode then press2(the button illumination flashes rapidly) +read card / tag, you will hear a double beep .bi ”, which means that the card / tag and the assigned PIN code have been successfully performed deleted.
3.3. Delete all cards.
Enter the programming mode then press2(the button illumination flashes rapidly) +88+#(you will hear a seven-time "bi" sound, the button illumination is slowly flashing), which means that all information has been deleted.
4. Adjustment of the deceleration time for Input 1.
Enter the programming mode then press4(the button illumination flashes rapidly) +00 ~ 99(select from the range e.g. 01) +#(you will hear a double “bi” sound, the button light is flashing slowly). Successful Exit 1 release time adjustment. If we enter the value 02, it means that Output 1 will be released for 2 seconds. If we enter the value 00 it means that we have to bring the card closer to open it and then bring it back to close it.
Example for a value of 4 seconds:
* 999999 # 404 #
5. Safety mode settings To disable the mode:
Press 5 (button illumination flashes quickly) +00+#(you will hear a double "bi" sound, the
button illumination is flashing slowly):
Security mode is disabled.
Lock Mode:
Press5(the button illumination flashes) +01+#(you will hear a double "bi" sound, the button illumination is flashing slowly):
If an invalid card is repeatedly presented within 5 minutes or 10 wrong passwords are entered, the device will be locked for 2 minutes, the button illumination will flash quickly and the connection to the indoor panel will be established automatically. During the
blockade, the device does not read cards and does not respond to pressing the buttons on the keyboard, with the exception of the bell button.
Emergency mode:
Press5(the button illumination flashes) +02+#(you will hear a double “bi” sound. button illumination flashes slowly): If an invalid card is presented repeatedly within 5 minutes or 10 wrong passwords are entered, the device will lock and alarm for 1 minute, the button illumination will flash quickly and the connection to the indoor panel will be established automatically. During the blockade, the device does not read cards and does not respond to pressing the buttons on the keyboard, with the exception of the bell button.
(!) ATTENTION!
While following the steps above, press "*" to exit or return to the previous step.
6. Changing the general password for Exit 2.
Enter the programming mode then press0(the button illumination flashes rapidly) +12+#+NNNNNN(6-digit password) +#+NNNNNN(re-enter password) +#.
Code example555555:*999999 # 012 # 555555 # 555555 #
7. Programming card / tag for Output 2.
Enter the programming mode then press7(the button illumination flashes rapidly) +000 ~ 099(choose from the range e.g. 001) +#+present the card / tag. you will hear a double "bi" sound, which means the card / tag has been added successfully. 4 beep. "Bi" means adding card failed. After adding a new card / tag, the factory default password is 0000.
This password is not used for access control, but for entering a new password.
To change the standard password, press *, hold the card / tag close to the reader and enter 0000 # (two "bi" signals), then enter a new 4-digit PIN code, confirming # and repeat the PIN code, confirming #.
Code example7777:
* keychain / card 0000 # 7777 # 7777 #
8. Deleting card and tag for Output 2.
8.1. Deleting a lost card / tag:
Enter the programming mode then press8(the button illumination flashes rapidly) +NNN+#(NNN means the number of any card / tag from 000 to 099 that you want to delete).
Triple "bi" sound means that the card / tag and the assigned PIN code have been deleted.
8.2. Deleting uploaded cards / tags:
Press8(the button illumination flashes rapidly) +read card / tag. you will hear a double beep .bi ”, which means that the card / tag and the assigned PIN code have been successfully deleted.
8.3. Deleting all cards:
Enter the programming mode then press8(the button illumination flashes rapidly) +88+# (you will hear a seven-time “bi” sound, the button light is flashing slowly), which means that all information has been deleted.
9. Output 2 release time adjustment.
Enter the programming mode then press9(the button illumination flashes rapidly) +00 ~ 99(select from range) +#(you will hear a double “bi” sound, the button light is flashing slowly). Exit 2 timing was successful. If we enter the value 02, it means that Output 2 will
be enabled for 2 seconds. If we enter the value 00 it means that we have to bring the card closer to open it and then bring it back to close it.
Example for a value of 4 seconds:
* 999999 # 904 #
10. Operation of the device by the user
(!) ATTENTION!
The following operations must be performed outside of programming mode.
Password change
Press *, present the card + enter the old PIN code + # (by default 0000, you will hear a double "bi" signal, the button backlight is slowly blinking). NNNN (4-digit code for new password).
Opening the door with a card / tag
Place a valid card / tag close to the reader on the cassette. The electric strike will be released.
Opening the door with a card / key ring or PIN code
Place a valid card / tag near the reader on the cassette or enter a 4-digit password on its keyboard. Accept by pressing #. If the card / tag or PIN code is correct, the electric strike will be released.
Opening the door with a card / tag and password
Present a valid card / tag to the reader on the cassette and enter a 4-digit password and accept by pressing #.
If the card / tag and PIN code are correct, the electric strike will be released.
Eura-Tech Sp. z o. o. hereby declares that the type of radio device - external cassette:
VDA-51C5 - is compliant with Directive
2014/53 / EU.
Full text of the EU declaration of conformity is available under the following web address:
www.eura-tech.eu
VDA-51C5 - is compliant with Directive
2014/53 / EU.
Full text of the EU declaration of conformity is available under the following web address:
www.eura-tech.eu
EURA-TECH Sp. z o.o.
ul. Przemysłowa 35A, 84-200 Wejherowo, Poland
www.eura-tech.eu
All rights reserved.
The pictures, drawings and texts used in this manual are the property of ‘EURA-TECH’ Sp. z o.o.
Reproduction, distribution and publication
of the whole or parts of the manual without the author's consent are prohibited!
The Eura-Tech Sp. z o.o. company reserves the right to change technical parameters and modify the operating instructions without notification.
At the same time, we would like to inform that the most up-to-date version of the manual can be found on the website www.eura-tech.eu
on the subpage of the given product.
The EU declaration of conformity of the given device is provided on the http://www.eura-tech.eu website